HERMES M100 Series

Designed for remote monitoring of industrial installations, the Hermes M100 series stands out for its flexibility and simplicity of implementation. All along with the free Zeus monitoring platform, it offers a complete solution for the management of unattended installations.

Its main functionalities are:

Alarm Transmission

Advanced alarm detection logic by threshold, time out of range and logical combinations among others.

Alarm transmission via SMS, voice call or PUSH notification to the ZeusMobile application.

Data logger

Memory for more than 150,000 input/output/event value records. Transmission to the Zeus platform via 4G mobile communication or Ethernet/Wi-Fi.

Automation

Powerful and intuitive programming language for automation with logical modules for pump control, communication between stations and twilight clock among others.

CHARACTERISTICS


  • Integrated 4G and Ethernet/WIFI communication
  • 8 digital inputs
  • 4 analog inputs
  • 2 digital outputs
  • Expandable up to 128 inputs/outputs
  • MODBUS RTU and MODBUS TCP interface
  • 150,000 log memory for data inputs.
  • Astronomical clock and logic module for pump control
  • 5 years warranty
MODELNETWORKSREGIONETHERNET/WIFICOMMENTS
M103.E4G.E2G/3G/4GEurope, Middle East and AsiaYESMaximum compatibility with mobile networks in Europe, the Middle East and Asia
M103.L4G.E2G/3G/4GLatin America and AustraliaYESMaximum compatibility with mobile networks in Latin America and Australia
M103.E4G.X2G/3G/4GEurope, Middle East and AsiaNO
Maximum compatibility with mobile networks in Europe, the Middle East and Asia
M103.L4G.X2G/3G/4GLatinoamƩrica y AustraliaNOMaximum compatibility with mobile networks in Latin America and Australia
M103.W2G-NB.E2G/NB-loT/LET-MWorldwideYESLow cost and excellent coverage. Network deployment not completed. SMS support not guaranteed. Does not allow voice call notifications
M103.W2G-NB.X
(Made upon request)
2G/NB-loT/LET-M
Worldwide
NO
Low cost and excellent coverage. Network deployment not completed. SMS support not guaranteed. Does not allow voice call notifications
MODELNETWORKSREGIONETHERNET/WIFI
M103.E4G.E2G/3G/4GEurope, Middle East and AsiaYES
M103.L4G.E2G/3G/4GLatin America and AustraliaYES
M103.E4G.X2G/3G/4GEurope, Middle East and AsiaNO
M103.L4G.X2G/3G/4GLatinoamƩrica y AustraliaNO
M103.W2G-NB.E2G/NB-loT/LET-MWorldwideYES
M103.W2G-NB.X
(Made upon request)
2G/NB-loT/LET-M
Worldwide
NO

Hermes M110

+8 DIGITAL INPUTS

Hermes M120

+4 ANALOG INPUTS

Hermes M121

+4 INPUTS FOR PT100 PROBES

Hermes M130

+6 DIGITAL RELAY OUTPUTS

Hermes M140

+4 ANALOG OUTPUTS

MODEL

CHARACTERISTIC

DOWNLOADS

Hermes M110

+ 8 DIGITAL INPUTS

Hermes M120

+ 4 ANALOG INPUTS

Hermes M121

+ 4 INPUTS FOR PT100 PROBES

Hermes M130

+ 6 DIGITAL RELAY OUTPUTS

Hermes M140

+ 4 ANALOG OUTPUTS 4/20mA

ACCESSORIES

UPS 2415

24 VDC and 15 W Uninterruptable Power Supply

F100-U PROBE

Smart capacitive probe for reliable detection of presence of discharges in spillways

VEGAPULS C11 / C21 / C22

Radar sensor for level measurement of liquids and bulk solids

STDV01 / STDV02

Probes for measuring ambient temperature and humidity

SONDA Y201 / Y203

Ultrasonic probe for non-contact liquid level measurement

SONDA HLM-25S

Submersible hydrostatic probe for measuring the level of non-aggressive liquids in pressureless tanks, wells, tanks, etc.

ANTENNAS

Antennas with different gains and extension cables

APPLICATIONS

STORAGE OF TREATED WATER

The system allows remote monitoring and sending of alarms for multiple parameters, including level, filling percentage, flow rate, pressure, chlorine, pH, among others.


The Publish/Subscribe functionality facilitates the exchange of data between different HERMES and NEMOS stations via the Zeus platform. In this way, the station that controls the pumping will have access to the data on the level of the tanks to be supplied. Thanks to this information, the automatic switching on of the pumps can be programmed to keep the tanks within the established levels.

PUMP STATIONS

Remote manual control and automatic control by tank levels and hourly rates.

COLD, AIR CONDITIONING AND HEAT PRODUCTION INSTALLATIONS

Automatic temperature monitoring and control to ensure service continuity and optimize energy costs.

UNINTERRUPTED SUPERVISION IN UNATENTED CONTROL CENTERS

Real-time visualization and recording of alarms and sensors from remote facilities.

INDOOR ENVIRONMENT QUALITY

Recording of sensors and manual/automatic control of the switching on of heaters, air extractors, lighting groups, etc., in offices and livestock farms.

AUTOMATION through MICRO PLC II

MicroPLC-II, Microcom’s new automation programming language, offers ease of use and efficiency unmatched in its sector. A simplified syntax and a set of logic modules that solve the most common problems are the keys to this ease of use. The language’s mathematical-logical engine supports a complete set of arithmetic, trigonometric and logical operators, thus providing great computing power. Its most notable features are:

Pump control module

Logic module for controlling up to 6 pumps, managing alternation, hour counter, start counter, maximum continuous operation time and pump inhibition inputs.

Inter-station communication module

Redundant system for the exchange of variables between stations. In case the main channel via GPRS/TCP-IP fails, a secondary channel is established via SMS.

Twilight Clock

Calculation of sunrise and sunset times based on the configured geographic coordinates.

Programmable timers

Five timer types natively supported by the language: on, off, accumulator, pulse, and weekly.

Pump-Tank Automation

Pump-tank communication via GPRS/TCP-IP with SMS redundancy. Pump alternation, start/stop thresholds according to hourly rates and control of pump failure and inhibition signals.

Pumping of waste water

Pump alternation management, start/stop thresholds based on hourly rates and control of fault signals, pump inhibition and low/high level float.

Street lighting

Lighting of luminaires according to astronomical clock with configurable offset for working and non-working days.

Ease of use and the use of the latest web technologies to offer an intuitive interface that is as secure as any online banking service are the most outstanding features of ZEUS, the online SCADA that Microcom makes available to its clients free of charge.
A simple web browser is all you need to access the service and start managing your facilities from anywhere. When you are out of the office, the ZEUSmobile mobile application available for iOS and Android facilitates, in addition to optimized access for phones and tablets, the reception of alarms using PUSH technology, making SMS obsolete in most cases.
ZEUS is not limited to visualization, it also allows the reconfiguration of remote stations without having to travel, the sending of orders or the management of users and stations. Integration into other platforms is guaranteed through the most common standards currently such as OPC UA and REST API.

TOOLS AND FEATURES

Viewing historical data in graphical format
Real-time monitoring using synoptics
Geolocated map of stations.

Complete reporting tool

Maximum security thanks to the most advanced web standards: HTTPs / SSL

Advanced user and privilege management

Easy data integration into other platforms using OPC UA and REST API

Receiving, managing and forwarding alarms

Remote configuration of Hermes and Nemos devices

Availability of the Zeus Synoptic Builder tool for creating synoptics.


Write to us and we will get in touch

In accordance with the provisions of REGULATION (EU) 2016/679 on the protection of personal data, we inform you that the data you provide us will be incorporated into the processing system owned by MICROCOM SISTEMAS MODULARES SL with CIF B26358036 and registered office at GOROSTIAGA, 53, for the purposes of ADVERTISING AND COMMERCIAL PROSPECTING; CUSTOMER MANAGEMENT, ACCOUNTING, TAX AND ADMINISTRATIVE. The data will be processed in a lawful, fair, transparent, adequate, pertinent, limited, exact and updated manner. Unless you tell us otherwise, we will understand that your data has not been modified and that you undertake to notify us of any variation. In accordance with the rights conferred on you by current regulations, you may exercise the rights of access, rectification, limitation of processing, deletion, portability and opposition to the processing of your personal data, as well as revoke the consent given, by sending your request to the indicated postal address or to the email address microcom@microcom.es and you may contact the competent Control Authority to file any claim you deem appropriate.*